Window Opening Width (mm) | Lintel Length (mm) | Lintel Height (mm) | Lintel Thickness (mm) |
900 | 1,200 | 200 | 100, 125, 150, 175, 200 |
1,200 | 1,600 | 200 | 100, 125, 150, 175, 200 |
1,600 | 1,900 | 200 | 100, 125, 150, 175, 200 |
1,800 | 2,200 | 300 | 100, 125, 150, 175, 200 |
2,100 | 2,700 | 300 | 100, 125, 150, 175, 200 |
Note :
1. The above information may subject to change.
2. Do not use the above information for calculating the transportation weight and volume.
Properties:
Modulus of Elasticity
2,190 MPa
Compressive Strength: 3.5 MPa
Thermal Conductivity: 0.172 W/m.K
Density: Dry 550 kg/m3
Working Density: 780 – 820 kg/m3